Showing posts with label protection. Show all posts
Showing posts with label protection. Show all posts
Friday, October 17, 2014
Simple OBD Vehicle Protection
Vehicle immobilisers are fitted as standard to modern cars and heavy goods vehicles. Anti-theft mechanisms have become more sophisticated but so have the methods employed by crooks. Nowadays once the thief has gained access to a vehicle they will most likely use an electronic deactivation tool which seeks to disable the immobiliser, once this has been accomplished a blank transponder key/card can be used to start the engine. In many cases communication with the immobiliser is made using the OBD-II diagnostic connector.
Although the OBD-II protocol itself does not support the immobiliser, the vehicle manufacturer is free to use the interface as neces-sary for communication, either the standard OBD-II signals or unused pins in the OBD-II connector (i.e. those undefined in the OBD-II standard). Using one of these pathways the immobiliser can usually be electronically disabled.
OBD Vehicle Protection Circuit Diagram
This may be unsettling news for owners of expensive vehicles but when professional car-thieves call, armed with the latest OBD-II hacking equipment this simple low-cost low-tech solution may be all that you need. The idea is ver y simple: if all connections to the OBD-II connector are disconnected there is no possibility for any equipment, no matter how sophisticated to gain access via the vehicle’s wiring.
The OBD-II connector is usually locate d underneath the dashboard on the passenger side; once its wiring loom has been identified a switch can be inserted in line with the wires. The switch should be hidden away some-where that is not obvious. In normal opera-tion you will be protected if the vehicle is run with the wires to the socket disconnected. Make sure however that you throw the switch reconnecting the socket before you next take the vehicle along to a garage for servicing or fault diagnosis.
The diagram shows the ISO K and ISO L wires switched. To cover all bases it is wise for every wire to the socket is made switchable except the two earth connections on pins 4 and 5 and the supply voltage on pin 16. Almost ever y vehicle manufacturer has their own method of vehicle immobilisation, by disconnecting every wire it ensures that no communication is possible (even over the CAN bus). Now the innermost workings of your vehicle will be safe from prying eyes. When a hacker plugs in a deactivation tool it will power up as normal but probably report something like ‘protocol unrecognised’ when any communication with the OBD port is attempted.
Author : Florian Schäffer - Copyright: Elektor
Sunday, October 5, 2014
5 Volt Regulated PSU Featuring Overvoltage Protection

Notes
The 5 volt regulated power supply for TTL and 74LS series integrated circuits, has to be very precise and tolerant of voltage transients. These ICs are easily damaged by short voltage spikes. A fuse will blow when its current rating is exceeded, but requires several hundred milliseconds to respond. This circuit will react in a few microseconds, triggered when the output voltage exceeds the limit of the zener diode.
This circuit uses the crowbar method, where a thyristor is employed and short circuits the supply, causing the fuse to blow. This will take place in a few microseconds or less, and so offers much greater protection than an ordinary fuse. If the output voltage exceed 5.6Volt, then the zener diode will conduct, switching on the thyristor (all in a few microseconds), the output voltage is therefore reduced to 0 volts and sensitive logic ICs will be saved. The fuse will still take a few hundred milliseconds to blow but this is not important now because the supply to the circuit is already at zero volts and no damage can be done. The dc input to the regulator needs to be a few volts higher than the regulator voltage. In the case of a 5v regulator, I would recommend a transformer with secondary voltage of 8-10volts ac.
The 5 volt regulated power supply for TTL and 74LS series integrated circuits, has to be very precise and tolerant of voltage transients. These ICs are easily damaged by short voltage spikes. A fuse will blow when its current rating is exceeded, but requires several hundred milliseconds to respond. This circuit will react in a few microseconds, triggered when the output voltage exceeds the limit of the zener diode.
This circuit uses the crowbar method, where a thyristor is employed and short circuits the supply, causing the fuse to blow. This will take place in a few microseconds or less, and so offers much greater protection than an ordinary fuse. If the output voltage exceed 5.6Volt, then the zener diode will conduct, switching on the thyristor (all in a few microseconds), the output voltage is therefore reduced to 0 volts and sensitive logic ICs will be saved. The fuse will still take a few hundred milliseconds to blow but this is not important now because the supply to the circuit is already at zero volts and no damage can be done. The dc input to the regulator needs to be a few volts higher than the regulator voltage. In the case of a 5v regulator, I would recommend a transformer with secondary voltage of 8-10volts ac.
Labels:
5,
featuring,
overvoltage,
protection,
psu,
regulated,
volt
Tuesday, September 9, 2014
Over voltage Protection for Logic Wiring diagram Schematic
Zener diode ZD1 senses the supply, and should the supply rise above 6 V, Ql will turn on. In turn, Q2 conducts clamping the rail. Subsequent events depend on the source supply. It will either shut down, go into current limit or blow its supply fuse. None of these will damage the TTL chips. The rating of Q2 depends on the source supply, and whether it will be required to operate continuously in the event of failure. Its current rating has to be in excess of the source supply.
Over voltage protection for logic Circuit Diagram

Saturday, August 30, 2014
Electronic Fuse for DC Short Circuit Protection
This schema will protect your power supply or battery. The electric current will stopped by relay when electric current short occured, Relays must be chosen with a voltage value equals to the input voltage. Dont omit using the 100uF capacitor with appropriate voltage value with respect to the input voltage. If you cant provide, you can use C106 instead of BRX46.
You can adjust the current with using 10K potentiometer. If you will use the fuse with very high currents, lower the 0R6 5W resistor value (ex. 0R47, 0R33, 0R22 or 0R1). Watt value of the resistor should be increased also.
Labels:
circuit,
dc,
electronic,
for,
fuse,
protection,
short
Monday, August 25, 2014
5 Volt Regulated PSU Featuring Overvoltage Protection
Notes
The 5 volt regulated power supply for TTL and 74LS series integrated diagram, has to be very precise and tolerant of voltage transients. These ICs are easily damaged by short voltage spikes. A fuse will blow when its current rating is exceeded, but requires several hundred milliseconds to respond. This schema will react in a few microseconds, triggered when the output voltage exceeds the limit of the zener diode.
This schema uses the crowbar method, where a thyristor is employed and short diagram the supply, causing the fuse to blow. This will take place in a few microseconds or less, and so offers much greater protection than an ordinary fuse. If the output voltage exceed 5.6Volt, then the zener diode will conduct, switching on the thyristor (all in a few microseconds), the output voltage is therefore reduced to 0 volts and sensitive logic ICs will be saved. The fuse will still take a few hundred milliseconds to blow but this is not important now because the supply to the schema is already at zero volts and no damage can be done. The dc input to the regulator needs to be a few volts higher than the regulator voltage. In the case of a 5v regulator, I would recommend a transformer with secondary voltage of 8-10volts ac.
The 5 volt regulated power supply for TTL and 74LS series integrated diagram, has to be very precise and tolerant of voltage transients. These ICs are easily damaged by short voltage spikes. A fuse will blow when its current rating is exceeded, but requires several hundred milliseconds to respond. This schema will react in a few microseconds, triggered when the output voltage exceeds the limit of the zener diode.
This schema uses the crowbar method, where a thyristor is employed and short diagram the supply, causing the fuse to blow. This will take place in a few microseconds or less, and so offers much greater protection than an ordinary fuse. If the output voltage exceed 5.6Volt, then the zener diode will conduct, switching on the thyristor (all in a few microseconds), the output voltage is therefore reduced to 0 volts and sensitive logic ICs will be saved. The fuse will still take a few hundred milliseconds to blow but this is not important now because the supply to the schema is already at zero volts and no damage can be done. The dc input to the regulator needs to be a few volts higher than the regulator voltage. In the case of a 5v regulator, I would recommend a transformer with secondary voltage of 8-10volts ac.
Labels:
5,
featuring,
overvoltage,
protection,
psu,
regulated,
volt
Saturday, August 9, 2014
Simple Overvoltage Protection Wiring diagram Schematic
Simple Over-voltage Protection Circuit Diagram. This schema is a safety schema This is a very simple Simple Over-voltage Protection Circuit Diagram. When testing a schema, a source of voltage that is variable and has over-voltage shutdown is very useful. In this schema, Rl is adjusted to 1 to 2 V below the eventual shutdown threshold. R2 sets the trip voltage. When this voltage is reached, the schema shuts the voltage to the schema under test down. To reset, reduce Rl below trip threshold and depress reset switch SI.
Simple Over-voltage Protection Circuit Diagram

Subscribe to: